-- ___________________________________________________________________________ -- $RCSfile: hsmmib.txt $ -- $Revision: 1.11 $ -- $Date: 2007/11/20 23:12:33Z $ -- $Author: edarosa $ -- -- Module Organization : -- This is a PRILIMINARY document whose contents are subject to change -- without prior notice. -- Radyne user MIB Object Identifiers description. The privite entereprise -- number 2591 is a unique identifier assigned to Radyne by the Internet -- Assigned Numbers Authority (IANA). This number is used to uniquely -- define vendor specific information such as private MIBs. -- -- Program Units : (list of program units) -- -- Requirements Trace : (document(s) and paragraph reference) -- -- Deviations : (any deviations from the coding standard) -- -- Revision History : adapted from 3030/3030L usermib -- ___________________________________________________________________________ RADYNE-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; -- groups in Radyne specific MIB radyne OBJECT IDENTIFIER ::= { enterprises 2591 } dvb3030 OBJECT IDENTIFIER ::= { radyne 1 } radSNMPModNVStatus OBJECT IDENTIFIER ::= { dvb3030 1 } radSNMPModStatus OBJECT IDENTIFIER ::= { dvb3030 2 } RadPowerLevel ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "Power level in tenths of a dBm." SYNTAX INTEGER RadVoltageLevel ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "Voltage level in tenths of a volt." SYNTAX INTEGER RadString ::= TEXTUAL-CONVENTION DISPLAY-HINT "255a" STATUS current DESCRIPTION "ASCII String." SYNTAX OCTET STRING RadInterfaceCardType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Terrestrial interface card type." SYNTAX INTEGER{ v1InSerialRs422( '01'h), v1InDirecTV( '02'h), v1InG703( '83'h), v1InHssi( '84'h), v1InAsiParallelRs422( '07'h), v1InAsiParallelLvds( '08'h), v1InIpsat( '89'h), piicInAsi( '93'h), piicInParallelRs422( '94'h), piicInParallelLvds( '95'h), piicInHssi( '96'h), piicInG703E1T1( '98'h), piicInG703E2T2( '99'h), piicInG703E3T3Sts1( '9A'h), piicInSerialRs422( '9B'h), piicInDirecTVAmc( '9C'h), piicInGigEthernet( '9D'h), piicOutAsi( 'D3'h), none( 'ff'h) } RadRadioFreqHz ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Radio Frequency in Hz." SYNTAX OCTET STRING radCarrierControl OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS current DESCRIPTION "Turns carrier on and off" ::= { radSNMPModNVStatus 1 } radTransmitPower OBJECT-TYPE SYNTAX RadPowerLevel (-300..50) ACCESS read-write STATUS current DESCRIPTION "Selects the Tx power level in tenths of dBm from +5.0 to -20.0 (70/140MHz), from -5.0 to -30.0 (L-Band). There is an implied decimal point. For example, a value of 39 represents a transmit power level of +3.9 dBm." ::= { radSNMPModNVStatus 2 } radIFFrequency OBJECT-TYPE SYNTAX INTEGER (50000000..1750000000) ACCESS read-write STATUS current DESCRIPTION "Selects IF frequency in Hz." ::= { radSNMPModNVStatus 3 } radDataRate OBJECT-TYPE SYNTAX INTEGER (0..238000000) ACCESS read-write STATUS current DESCRIPTION "Selects the data rate in bps. Note: Changing data rate will affect symbol rate, see comment at the end of mibtext." ::= { radSNMPModNVStatus 4 } radSymbolRate OBJECT-TYPE SYNTAX INTEGER (0..68000000) ACCESS read-write STATUS current DESCRIPTION "Selects the symbol rate in sps." ::= { radSNMPModNVStatus 5 } radSymbolRateMode OBJECT-TYPE SYNTAX INTEGER { variable(0), fixed(1) } ACCESS read-write STATUS optional DESCRIPTION "Selects symbol rate mode. This can only be modified if the factory configuration is set to both variable and fixed. This is obsolete." ::= { radSNMPModNVStatus 6 } radStrapCode OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS optional DESCRIPTION "The strap code is a quick set key that sets many modem parameters. Not implemented." ::= { radSNMPModNVStatus 7 } radConvolutionalEncoder OBJECT-TYPE SYNTAX INTEGER { none(0), ifecRate1x2(1), ifecRate2x3(2), ifecRate3x4(3), ifecRate5x6(4), ifecRate7x8(5), ifecRate6x7(6), ifecRate8x9(8), ifecRate9x10(9), ifecRate1x4(128), ifecRate1x3(129), ifecRate2x5(130), ifecRate3x5(131) } ACCESS read-write STATUS current DESCRIPTION "Selects Tx code rate and type. Note: Changing the convolutional encoder will affect symbol rate and data rate. See note at the end of this section. Unsupported choices include: none viterbi6x7 " ::= { radSNMPModNVStatus 8 } radClockControl OBJECT-TYPE SYNTAX INTEGER { scte(0), sct(1), none(2) } ACCESS read-write STATUS current DESCRIPTION "Selects Tx clock source. 0 selects terrestrial clock (SCTE), 1 selects internal clock (SCT). Modulators using ASI or G.703 interface options must use SCTE at all times." ::= { radSNMPModNVStatus 9 } radFramingMode OBJECT-TYPE SYNTAX INTEGER { framing188Byte (0), framing204Byte (1), framingNone (2), framingDirecPc (3), framingDirecTv (4), framingProMpegCop3 (5), framingProMpegAcm (6), framingBridge (7) } ACCESS read-write STATUS current DESCRIPTION "Selects the frame transport stream input type. Note: Changing the framing mode will affect the symbol rate and/or data rate. See note at the end of this section." ::= { radSNMPModNVStatus 10 } radRolloff OBJECT-TYPE SYNTAX INTEGER { rolloff0point35 (0), rolloff0point2 (1), rolloff0point25 (25) } ACCESS read-write STATUS current DESCRIPTION "0 selects alpha factor rolloff of 0.35, '1' selects alpha factor rolloff of 0.2, '25' selects alpha factor rolloff of 0.25" ::= { radSNMPModNVStatus 11} radFreqReferenceSource OBJECT-TYPE SYNTAX INTEGER { internal(0), external(1) } ACCESS read-write STATUS current DESCRIPTION "Selects internal or external reference clock" ::= { radSNMPModNVStatus 12 } radExternalReference OBJECT-TYPE SYNTAX INTEGER (256000..10000000) ACCESS read-write STATUS current DESCRIPTION "Selects the external reference frequency in Hz with a 8000Hz step size." ::= { radSNMPModNVStatus 13 } radInterfaceType OBJECT-TYPE SYNTAX INTEGER { serial(0), asiNorm(2), asiNull(3), g703E3(4), g703T3(5), sts1(6), hssi(7), parallelDVB(8), parallelM2P(9), none(10), directv(11), oc3(13), stm1(14), g703E2(15), g703T2Bal(16), g703T2Unbal(17), g703E1Bal(18), g703E1Unbal(19), g703T1AMI(20), g703T1B8ZS(21), gigEthernet(22) } ACCESS read-write STATUS current DESCRIPTION "Selects the various interface types. The following choices are not supported: none(10), oc3(13), stm1(14) Note: Selecting interface types Parallel DVB, Parallel M2P, Serial, DirecTv or HSSI will force the outclock selection to SCT. Selecting interface type ASI Norm or ASI Null causes the outclock selection to be forced to None. " ::= { radSNMPModNVStatus 14 } radClockPolarity OBJECT-TYPE SYNTAX INTEGER { normal(0), inverted(1) } ACCESS read-write STATUS current DESCRIPTION "Selects clock polarity for Tx terrestrial clock relative to Tx data." ::= { radSNMPModNVStatus 15 } radDataPolarity OBJECT-TYPE SYNTAX INTEGER { normal(0), inverted(1) } ACCESS read-write STATUS current DESCRIPTION "Selects data polarity" ::= { radSNMPModNVStatus 16} radSpectrum OBJECT-TYPE SYNTAX INTEGER { inverted(0), normal(1) } ACCESS read-write STATUS current DESCRIPTION "Inverts the symbol mapping direction of rotation." ::= { radSNMPModNVStatus 17 } radModulationType OBJECT-TYPE SYNTAX INTEGER { qpsk(0), bpsk(1), psk8(2), qam16(3), apsk16(9), apsk32(10) } ACCESS read-write STATUS current DESCRIPTION "Selects the modulation type. Note: Changing modulation type will affect the symbol rate and data rate. See note at the end of this section." ::= { radSNMPModNVStatus 18} radFraming OBJECT-TYPE SYNTAX INTEGER { dvb(0) } ACCESS read-write STATUS optional DESCRIPTION "This selection is reserved and is superceeded by satFraming. Please refer to radSNMPModNVStatus.69 for more information." ::= { radSNMPModNVStatus 19 } radReedsolomon OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Enables the ReedSolomon encoder. Reserved" ::= { radSNMPModNVStatus 20 } radScramblerControl OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Enables scrambler operation" ::= { radSNMPModNVStatus 21 } radScramblerType OBJECT-TYPE SYNTAX INTEGER { dvb(0) } ACCESS read-write STATUS optional DESCRIPTION "Selects scrambler type. Not implemented" ::= { radSNMPModNVStatus 22 } radDifferentialEncoder OBJECT-TYPE SYNTAX INTEGER { off(0) } ACCESS read-write STATUS optional DESCRIPTION "Disables differential encoder unsupported " ::= { radSNMPModNVStatus 23 } radAlarmMaskEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS optional DESCRIPTION "unsupported" ::= { radSNMPModNVStatus 24 } radMajorAlarmMask OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS current DESCRIPTION "Major Alarm mask: A bit field. 0 = MASKED, 1 = UNMASKED Bit 1 = Oversample Clock PLL Lock Bit 2 = FPGA Configuration Error Bit 3 = Synthesis Clock PLL Lock Bit 4 = External Reference PLL Lock Bit 5 = Composite PLL Lock Bit 6 = Symbol PLL Lock Bit 7 = Invalid Terrestrial Interface " ::= { radSNMPModNVStatus 25 } radMinorAlarmMask OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS current DESCRIPTION "Minor Alarm mask: A bit field. 0 = MASKED, 1 = UNMASKED Bit 0 = Terr Ethernet data activity detect Bit 1 = Terrestrial clock activity detect Bit 2 = Tx data activity detect Bit 3 = FIFO overflow/underflow error Bit 4 = Output Level Bit 5 = Loss of frame synchronization Bit 6 = Terr Ethernet jitter buffer underflow Bit 7 = Terr Ethernet jitter buffer overflow " ::= { radSNMPModNVStatus 26 } radCommonAlarmMask OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS current DESCRIPTION "Common Alarm mask: A bit field. 0 = MASKED, 1 = UNMASKED Bit 0 = -12V alarm. Bit 1 = +12V alarm. Bit 2 = +5V alarm. " ::= { radSNMPModNVStatus 27 } radOperatingMode OBJECT-TYPE SYNTAX INTEGER { normal(0), testPattern2To15Minus1(1), testPattern2To23Minus1(23) } ACCESS read-write STATUS current DESCRIPTION "Test Pattern Operating Mode: None, (2^15)-1, (2^23)-1 " ::= { radSNMPModNVStatus 28 } radCarrierTest OBJECT-TYPE SYNTAX INTEGER { normal(0), cw(1), dual(2), offset(3), posfir(4), negfir(5) } ACCESS read-write STATUS current DESCRIPTION "normal, allows normal modulated data output cw, causes the modulator to output pure carrier dual, causes a double sideband output offset, causes a single side band output posfir, uses a positive FIR negfir, uses a negative FIR" ::= { radSNMPModNVStatus 29 } radCircuitID OBJECT-TYPE SYNTAX RadString (SIZE (11)) ACCESS read-write STATUS optional DESCRIPTION "Provides entry of Tx circuit identifier. Circuits can be given up to 11 character alphanumeric identity such as LINK1. Not implemented." ::= { radSNMPModNVStatus 30 } radControlMode OBJECT-TYPE SYNTAX INTEGER { local(0), terminal(1), computer(2), ethernet(3) } ACCESS read-write STATUS optional DESCRIPTION "Selects the active control source. This is obsolete." ::= { radSNMPModNVStatus 31 } radMode OBJECT-TYPE SYNTAX INTEGER { dvb(0), direcpc(1), directv(9), dvbs2BsNbc(11), dvbs2BsBc(12), directvAmcNbc(13), directvAmcBc(14), dvbs2Nbs(15) } ACCESS read-write STATUS current DESCRIPTION "Selects the network specification." ::= { radSNMPModNVStatus 32 } radInterleaver OBJECT-TYPE SYNTAX INTEGER { enable(0), disable(1) } ACCESS read-write STATUS current DESCRIPTION "Enables or disables the interleaver." ::= { radSNMPModNVStatus 33 } radOutClockSelection OBJECT-TYPE SYNTAX INTEGER { scte(0), sct(1), none(2) } ACCESS read-write STATUS current DESCRIPTION "Selects the source of clock output from the Terrestrial Interface. See the Clock Source Selection Matrix." ::= { radSNMPModNVStatus 34 } radLastRateControl OBJECT-TYPE SYNTAX INTEGER { symbol(0), data(1), auto(2) } ACCESS read-write STATUS current DESCRIPTION "Allows the modulator to behave with symbol rate or data rate precedence based on the selection. See rate control notes." ::= { radSNMPModNVStatus 35 } radClearLatchedAlarms OBJECT-TYPE SYNTAX INTEGER { clearAlarms(1) } ACCESS read-write STATUS current DESCRIPTION "Clears all latched alarms." ::= { radSNMPModNVStatus 36 } radPcrRestamping OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS current DESCRIPTION "Enables the PCR restamping in AASI." ::= { radSNMPModNVStatus 37 } radMultiPiicMode OBJECT-TYPE SYNTAX INTEGER { manual(1), redundancy(2) } ACCESS read-write STATUS current DESCRIPTION "Selects the Multi-PIIC mode." ::= { radSNMPModNVStatus 38 } radRedundancyMode OBJECT-TYPE SYNTAX INTEGER { forcePrime(0), forceBackup(1), manualRevert(2), autoRevert(3) } ACCESS read-write STATUS current DESCRIPTION "Selects the Redundancy submode if the Multi-PIIC mode is redundancy." ::= { radSNMPModNVStatus 39 } radPrimePiicSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "If the Multi-PIIC mode is manual, radPrimePiicSlot selects the input slot. If the Multi-PIIC mode is redundancy, radPrimePiicSlot selects the prime input slot." ::= { radSNMPModNVStatus 40 } radBackupPiicSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS current DESCRIPTION "If the Multi-PIIC mode is redundancy, radBackupPiicSlot selects the backup input slot." ::= { radSNMPModNVStatus 41 } radRadioFrequencyHz OBJECT-TYPE SYNTAX Counter64 ACCESS read-write STATUS current DESCRIPTION "Selects RF frequency in Hz." ::= { radSNMPModNVStatus 42 } radLoFrequencyHz OBJECT-TYPE SYNTAX Counter64 ACCESS read-write STATUS current DESCRIPTION "Selects LO frequency in Hz." ::= { radSNMPModNVStatus 43 } radLowSideMix OBJECT-TYPE SYNTAX INTEGER { highSide(0), lowSide(1) } ACCESS read-write STATUS current DESCRIPTION "Selects the high-side/low-side LO mix." ::= { radSNMPModNVStatus 44 } radLocalIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the local IP address." ::= { radSNMPModNVStatus 45 } radPilotSymbolsEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Enables/disables pilot symbols at the physical layer." ::= { radSNMPModNVStatus 46 } radPhysLayerScramblerBypass OBJECT-TYPE SYNTAX INTEGER { normal(0), bypassed(1) } ACCESS read-write STATUS current DESCRIPTION "Enables/disables the physical layer scrambler. The modulator is considered in a test mode when the scrambler is bypassed." ::= { radSNMPModNVStatus 47 } radInnerFecBypass OBJECT-TYPE SYNTAX INTEGER { normal(0), bypassed(1) } ACCESS read-write STATUS current DESCRIPTION "Enables/disables the inner forward error correction. The modulator is considered in a test mode when the inner FEC is bypassed." ::= { radSNMPModNVStatus 48 } radRfSwitchRedundancyMode OBJECT-TYPE SYNTAX INTEGER { manual(1), autoRevert(2), backup(3) } ACCESS read-write STATUS current DESCRIPTION "If the modulator is connected to the prime side of the switch then manual and auto revert modes are available. Otherwise, if modulator is connected to backup side then only manual and backup modes are available." ::= { radSNMPModNVStatus 49 } radRfSwitchActivateSide OBJECT-TYPE SYNTAX INTEGER { primary(1), backup(2) } ACCESS read-write STATUS current DESCRIPTION "Activates the primary or backup side of the RF switch." ::= { radSNMPModNVStatus 50 } radRfSwitchFaultTestMode OBJECT-TYPE SYNTAX INTEGER { normal(1), faulted(2) } ACCESS read-write STATUS current DESCRIPTION "Allows the assertion of the fault signal to the RF switch for test purposes" ::= { radSNMPModNVStatus 51 } radPhaseNoiseGeneratorEnabled OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS current DESCRIPTION "Enables/disables the phase noise generator." ::= { radSNMPModNVStatus 52 } radPhaseNoiseProfileIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS current DESCRIPTION "Selects the phase noise profile." ::= { radSNMPModNVStatus 53 } radPlHeaderScramblerSeqIndex OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-write STATUS current DESCRIPTION "Selects the directv physical layer header scrambler sequence index." ::= { radSNMPModNVStatus 54 } radGoldCodeSeqIndex OBJECT-TYPE SYNTAX INTEGER (0..262142) ACCESS read-write STATUS current DESCRIPTION "Selects the gold code sequence index." ::= { radSNMPModNVStatus 55 } radTerrEthMode OBJECT-TYPE SYNTAX INTEGER { udp(0), cop3(1), cop3Fec(2) } ACCESS read-write STATUS current DESCRIPTION "Selects mode for the Gig Ethernet card." ::= { radSNMPModNVStatus 56} radTerrEthSelect OBJECT-TYPE SYNTAX INTEGER { prime(0), backup(1) } ACCESS read-write STATUS current DESCRIPTION "Selects prime or backup for the Gig Ethernet card." ::= { radSNMPModNVStatus 57 } radTerrEthJitterSz OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS current DESCRIPTION "Selects the jitter buffer size in 10ms steps." ::= { radSNMPModNVStatus 58 } radTerrEthJitterTrack OBJECT-TYPE SYNTAX INTEGER { widest(0), wide(1), midLevel(2), narrow(3), narrowest(4) } ACCESS read-write STATUS current DESCRIPTION "Selects the jitter tracking value from wide to narrow." ::= { radSNMPModNVStatus 59 } radTerrEthRevert OBJECT-TYPE SYNTAX INTEGER { manual(0), auto(1) } ACCESS read-write STATUS current DESCRIPTION "Selects the backup mode for the Gig Ethernet card." ::= { radSNMPModNVStatus 60 } radTerrEthBkupDly OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS current DESCRIPTION "Selects the backup delay in 100ms steps for the Gig Ethernet card." ::= { radSNMPModNVStatus 61 } radTerrEthAddrPrime OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the prime IP address for the Gig Ethernet card." ::= { radSNMPModNVStatus 62 } radTerrEthUdpPortPrime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS current DESCRIPTION "Selects the prime UDP port for the Gig Ethernet card." ::= { radSNMPModNVStatus 63 } radTerrEthSourcePrime OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the prime source IP address for the Gig Ethernet card." ::= { radSNMPModNVStatus 64 } radTerrEthAddrBackup OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the backup IP address for the Gig Ethernet card." ::= { radSNMPModNVStatus 65 } radTerrEthUdpPortBackup OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS current DESCRIPTION "Selects the backup UDP port for the Gig Ethernet card." ::= { radSNMPModNVStatus 66 } radTerrEthSourceBackup OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the backup source IP address for the Gig Ethernet card." ::= { radSNMPModNVStatus 67 } radTerrEthAddrUnicast OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the Unicast IP address for the Gig Ethernet card." ::= { radSNMPModNVStatus 68 } radSatFraming OBJECT-TYPE SYNTAX INTEGER { dvbs(0), dvbs2Normal(1), dvbs2Short(2), dssDtv(3) } ACCESS read-write STATUS current DESCRIPTION "Selects the satellite framing. SatFraming is valid in every radMode (networkSpec), except DVB-S2-NBS. In that configuration, the framing is automatically determined by the incoming stream." ::= { radSNMPModNVStatus 69 } radServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS current DESCRIPTION "Selects the IP address for the SNMP Trap Server." ::= { radSNMPModNVStatus 70 } ---------------------------------------------------------------------------- -- Status information out of Radyne specific MIB radMajorAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Major Alarm status: A bit field. 0 = PASS, 1 = FAIL Bit 1 = Oversample Clock PLL Lock Bit 2 = FPGA Configuration Error Bit 3 = Synthesis Clock PLL Lock Bit 4 = External Reference PLL Lock Bit 5 = Composite PLL Lock Bit 6 = Symbol PLL Lock Bit 7 = Invalid Terrestrial Interface " ::= { radSNMPModStatus 1 } radMinorAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Minor Alarm status: A bit field. 0 = PASS, 1 = FAIL Bit 0 = Terr Ethernet data activity detect Bit 1 = Terrestrial clock activity detect Bit 2 = Tx data activity detect Bit 3 = FIFO overflow/underflow error Bit 4 = Output Level Bit 5 = Loss of frame synchronization Bit 6 = Terr Ethernet jitter buffer underflow Bit 7 = Terr Ethernet jitter buffer overflow " ::= { radSNMPModStatus 2 } radCommonAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Common Alarm status: A bit field. 0 = PASS, 1 = FAIL Bit 0 = -12V alarm. Bit 1 = +12V alarm. Bit 2 = +5V alarm. " ::= { radSNMPModStatus 3 } radLatchedMajorAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Major Alarm latched status: A bit field. 0 = PASS, 1 = FAIL Bit 1 = Oversample Clock PLL Lock Bit 2 = FPGA Configuration Error Bit 3 = Synthesis Clock PLL Lock Bit 4 = External Reference PLL Lock Bit 5 = Composite PLL Lock Bit 6 = Symbol PLL Lock Bit 7 = Invalid Terrestrial Interface " ::= { radSNMPModStatus 4 } radLatchedMinorAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Minor Alarm latched status: A bit field. 0 = PASS, 1 = FAIL Bit 0 = Terr Ethernet data activity detect Bit 1 = Terrestrial clock activity detect Bit 2 = Tx data activity detect Bit 3 = FIFO overflow/underflow error Bit 4 = Output Level Bit 5 = Loss of frame synchronization Bit 6 = Terr Ethernet jitter buffer underflow Bit 7 = Terr Ethernet jitter buffer overflow " ::= { radSNMPModStatus 5 } radLatchedCommonAlarmStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS current DESCRIPTION "Common Alarm latched status: A bit field. 0 = PASS, 1 = FAIL Bit 0 = -12V alarm. Bit 1 = +12V alarm. Bit 2 = +5V alarm. " ::= { radSNMPModStatus 6 } radRevisionNumber OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS optional DESCRIPTION "M&C Revision number." ::= { radSNMPModStatus 7 } radPlus5Volts OBJECT-TYPE SYNTAX RadVoltageLevel (0..255) ACCESS read-only STATUS current DESCRIPTION "+5V monitor with implied decimal point. For example, a value of 51 represents +5.1 Volts." ::= { radSNMPModStatus 8 } radPlus12Volts OBJECT-TYPE SYNTAX RadVoltageLevel (0..255) ACCESS read-only STATUS current DESCRIPTION "+12V monitor with implied decimal point. For example, a value of 119 represents +11.9 Volts." ::= { radSNMPModStatus 9 } radMinus12Volts OBJECT-TYPE SYNTAX RadVoltageLevel (-255..0) ACCESS read-only STATUS current DESCRIPTION "-12V monitor with implied decimal point. For example, a value of -122 represents -12.2 Volts." ::= { radSNMPModStatus 10 } radTemperature OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS optional DESCRIPTION "Temperature monitor with implied decimal point. For example, a value of 490 represents 49.0 C" ::= { radSNMPModStatus 11 } radFactoryConfiguration OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS optional DESCRIPTION "A bit field that shows the factory configuration options. 0=No, 1=Yes. Bit 0 = Serial Interface Present Bit 1 = Parallel Interface Bit 2 = ASI Norm Interface Bit 3 = ASI Null Interface Bit 4 = E3 Interface Present Bit 5 = T3 Interface Present Bit 6 = STS-1 Interface Present Bit 7 = HSSI Interface Present Bit 8 = DSS Option Enabled Bit 9 = SNMP Option Enabled Bit 10 = Parallel DVB Present Bit 11 = Parallel M2P Present Bit 12 = DVB LVDS Present Bit 13 = OC3 Interface Present Bit 14..15 = Spares unsupported" ::= { radSNMPModStatus 12 } radLastRateStatus OBJECT-TYPE SYNTAX INTEGER { symbol(0), data(1) } ACCESS read-only STATUS current DESCRIPTION "Shows the current rate precedence. See Last Rate Control notes." ::= { radSNMPModStatus 13 } radFirmwarePartRev OBJECT-TYPE SYNTAX RadString (SIZE (16)) ACCESS read-only STATUS current DESCRIPTION "Provides the system firmware part and revision number." ::= { radSNMPModStatus 14 } radActivePiicSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Indicates the active PIIC slot." ::= { radSNMPModStatus 15 } -- radPiicSlotStatusTable OBJECT-TYPE -- SYNTAX SEQUENCE OF RadPiicSlotStatusEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "PIIC slot status table" -- ::= { radSNMPModStatus 16 } -- -- radPiicSlotStatusEntry OBJECT-TYPE -- SYNTAX RadPiicSlotStatusEntry -- ACCESS not-accessible -- STATUS optional -- DESCRIPTION -- "PIIC slot status table entry" -- INDEX { radPiicSlotStatusIndex } -- ::= { radPiicSlotStatusTable 1 } -- -- RadPiicSlotStatusEntry ::= -- SEQUENCE { -- radPiicSlotStatusIndex INTEGER, -- radPiicSlotCardType RadInterfaceCardType, -- radPiicSlotClockActivity INTEGER, -- radPiicSlotDataActivity INTEGER -- } -- -- radPiicSlotStatusIndex OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Index for radPiicSlotStatusTable." -- ::= { radPiicSlotStatusEntry 1 } -- -- radPiicSlotCardType OBJECT-TYPE -- SYNTAX RadInterfaceCardType -- ACCESS read-only -- STATUS current -- DESCRIPTION -- "Indicates the type of interface card in a slot." -- ::= { radPiicSlotStatusEntry 2 } -- -- radPiicSlotClockActivity OBJECT-TYPE -- SYNTAX INTEGER { -- inactive( 0), -- active( 1) -- } -- ACCESS read-only -- STATUS current -- DESCRIPTION -- "Indicates clock activity of an interface card in a slot." -- ::= { radPiicSlotStatusEntry 3 } -- -- radPiicSlotDataActivity OBJECT-TYPE -- SYNTAX INTEGER { -- inactive( 0), -- active( 1) -- } -- ACCESS read-only -- STATUS current -- DESCRIPTION -- "Indicates data activity of an interface card in a slot." -- ::= { radPiicSlotStatusEntry 4 } radRfSwitchActiveSide OBJECT-TYPE SYNTAX INTEGER { primary(1), backup(2) } ACCESS read-only STATUS current DESCRIPTION "Indicates the active input of the RF switch." ::= { radSNMPModStatus 17 } radRfSwitchDistantSideFault OBJECT-TYPE SYNTAX INTEGER { normal(1), faulted(2) } ACCESS read-only STATUS current DESCRIPTION "Indicates the fault status of the modulator at the distant side of the RF switch." ::= { radSNMPModStatus 18 } radRfSwitchConnectorSide OBJECT-TYPE SYNTAX INTEGER { primary(1), backup(2) } ACCESS read-only STATUS current DESCRIPTION "Indicates the side of the RF switch to which the modulator is connected." ::= { radSNMPModStatus 19 } radTerrEthPortStatus OBJECT-TYPE SYNTAX INTEGER { down(0), unresolved(1), half10m(2), half100m(3), full10m(4), full100m(5), half1gig(6), full1gig(7) } ACCESS read-only STATUS current DESCRIPTION "Shows the link status of the active Gig Ethernet card." ::= { radSNMPModStatus 20 } radTerrEthActPrime OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the data activity of the Gig Ethernet card." ::= { radSNMPModStatus 21 } radTerrEthActPrimeCol OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the data activity of the Gig Ethernet card." ::= { radSNMPModStatus 22 } radTerrEthActPrimeRow OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the data activity of the Gig Ethernet card." ::= { radSNMPModStatus 23 } radTerrEthActBackup OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the backup data activity of the Gig Ethernet card." ::= { radSNMPModStatus 24 } radTerrEthActBackupCol OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the backup data activity of the Gig Ethernet card." ::= { radSNMPModStatus 25 } radTerrEthActBackupRow OBJECT-TYPE SYNTAX INTEGER { disabled(0), noActivity(1), onlineActivity(2), offlineActivity(3) } ACCESS read-only STATUS current DESCRIPTION "Shows the backup data activity of the Gig Ethernet card." ::= { radSNMPModStatus 26 } radTerrEthJitterFill OBJECT-TYPE SYNTAX INTEGER (0..99) ACCESS read-only STATUS current DESCRIPTION "Percent fill of jitter buffer for the Gig Ethernet card." ::= { radSNMPModStatus 27 } radTerrEthNullPkts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS current DESCRIPTION "Null packet count for the Gig Ethernet card." ::= { radSNMPModStatus 28 } radTerrEthCorrPkts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS current DESCRIPTION "Corrected packet count for the Gig Ethernet card." ::= { radSNMPModStatus 29 } radTerrEthReorPkts OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS current DESCRIPTION "Reordered packet count for the Gig Ethernet card." ::= { radSNMPModStatus 30 } radTerrEthClrStats OBJECT-TYPE SYNTAX INTEGER { toggle0(0), toggle1(1) } ACCESS read-write STATUS current DESCRIPTION "Clears the Gig Ethernet card statistics." ::= { radSNMPModStatus 31 } END